Series-1 Mar. – Apr. 2022 Issue Statistics
- Citation
- Abstract
- Reference
- Full PDF
Abstract: Research has been carried out to uncover the failure of groundwater drilling with the help of the geoelectric method at Pondok Pesantren At Taqwiin Karangasem Bali. The problem that lies behind this research is that the Pondok Pesantren At Taqwiin previously had a small cubang as a water source for washing and bathing purposes. Cubang's water conditions are relatively good with a TDS of 146 ppm, and lime of 130 ppm. Next to the cottage there is also a river whose water flows all year round. The land next to the hut is also always wet so the trees can thrive. Paying attention to such a situation, the cottage party in the manufacture of drilled wells immediately carried out drilling. Finally, up to a depth of 140 m, there is no source of water yet. After that, the drilling was stopped. Taking into account this situation, the question can be asked, namely: Why has no water source been found until a depth.......
Key Word: groundwater, cubang, geoelectric, failure, drilling.
[1]. Cahyadi, A. dan Hidayat, W. 2017. Analisis Karakteristik Hidrogeokimia Airtanah di Pulau Koral Panggang, Kepulauan Seribu, DKI. Jakarta. Jurnal Geografi, 9(2): 99-108.
[2]. Setiawan, T., dan N.M. A. Asgaf. 2016. Analisis Karakteristik Akuifer Dan Zonasi Kuantitas Air Tanah di Dataran Kars Wonosari dan Sekitarnya Kabupaten Gunungkidul, Provinsi Daerah Istimewa Yogyakarta. Jurnal Lingkungan dan Bencana Geologi, 7(3), Desember 2016: 145 -154
[3]. Cahyadi, A. 2012. Permasalahan Sumberdaya Air di Pulau Karang Sangat Kecil (Studi Kasus di Pulau Pramuka, Kabupaten Kepulauan Seribu, DKI Jakarta). Prosiding Seminar Nasional Pengelolaan Sumberdaya Alam dan Lingkungan. Semarang: Program Studi Ilmu Lingkungan Universitas Diponegoro.
[4]. Karunia, D.K., Darsono, Darmanto. 2012. Identifikasi Pola Aliran Sungai Bawah Tanah di Mudah, Pracimantoro dengan Metode Geolistrik. Indonesian Journal of Applied Physics. 2(2): 91-101.
[5]. Simpen, I N dan I W. Redana. 2016. Pendugaan Posisi Akuifer dengan Metode Geolistrik dalam Rangka Membuat Sumur Bor di Villa Puri Persada Denpasar. Laboratorium Mekanika Tanah Jurusan Teknik Sipil Fakultas Teknik Universitas Udayana. Denpasar..
- Citation
- Abstract
- Reference
- Full PDF
Abstract: A very low frequency electromagnetic (VLF-EM) method was carried out to ascertain the level of contamination and pollution potential of a partially reclaimed dumpsite in Anantigha community in Calabar South Local Government Area of Cross River State. A portable electromagnetic receiver (Geonics EM 16N) was used to acquire data in ten traverses measuring up to 100m for eight traverses and 200m for two traverses around the dump vicinity. Electromagnetic wave response was recorded as in-phase and quadrature components of the field. Qualitative data interpretation was carried out using Karous –Hjelt software. VLF curves produced showed minor fracture planes in the area.......
Key Word: quadrature component; conductive zones; in-phase; control stations; leachate contaminants
[1]. Amajor, L.C. (1986). Alluvial fan facies in the Miocene-Pliocene coastal plain sands, Niger Delta, Nigeria. Sedimentary Geology. 49:1-20.
[2]. Benson A.K., Payne, K.I., and Stubben, M.A. (1997). Mapping Ground Water Contamination using DC Resistivity and VLF Geophysical Methods. A case study, Journal of Geophysics, 62(1):80-86.
[3]. Beyene, H. and Benerjee, S. (2011). "Assessment of the pollution status of the solid waste disposal site of Addis Ababa City with some selected trace elements, Ethiopia." World Applied Sciences Journal. 14 (7):1048-1057
[4]. Drahor, M.G. (2006). Integrated geophysical studies in the upper part of Sardis archaeological site, Turkey. J. Appl. Geophys. 59: 205-223.
[5]. Dimitriou, E., Karaouzas, I., Saratakos, I., Zacharias, I., Bogdanos, K. and Diapoulis, A. (2008) "Groundwater risk assessment at a heavily industrialized catchment and the associated impacts on a Peri-Urban wetland," Journal of Environmental Management, 88 (3): 526–538..
- Citation
- Abstract
- Reference
- Full PDF
| Paper Type | : | Research Paper |
| Title | : | Aquifer Vulnerability Assessment in Some Parts of Awka, South Eastern Nigeria |
| Country | : | Nigeria |
| Authors | : | Obiajulu,O. O || Nwaka , E.G |
| : | 10.9790/0990-1002012025 ![]() |
Abstract: A geophysical survey using electrical resistivity method was conducted to assess the vulnerability of aquifer in some parts of Awka, South Eastern, Nigeria. The Schlumberger array was adopted, vertical electrical sounding (VES) data were collected at twelve (12) locations with maximum current electrode spacing (AB) of 600m. The instrument used was Mc Ohm resistivity meter, a digital instrument for direct current resistivity work. The interpretation was done using software called IP2win. The results revealed that depth to aquifer ranged between 23.08 and 81.41m, resistivity of aquifer ranged between 452.9 and 2249.71Ωm. The interpreted parameters (resistivity and thickness) were......
Key Word: Aquifer, Vertical Electrical Sounding, Resistivity method, Longitudinal Conductance
[1]. Akana, T. S., George, G. C. and Oki, O. A. (2016). Aquifer vulnerability assessment in some towns of Yenagoa, South- South, Nigeria. Journal of Science and Technology 6 (1) 15-23.
[2]. Akpan, M. L., Abu, M. and Nasir, A. N. (2018). Vulnerability assessment of groundwater to contamination using electrical resistivity method at the Open Dumpsite in Gosa, Abuja, Nigeria. Journal of Geology and Geophysics7(2).
[3]. Dobrin, M. B (1983). Introduction to Geophysical prospecting. McGraw Int. Books Company. Tokyo. 70-107.
[4]. Egboka, B. C. E.and Okpoko, E. I. (1999). Conjunctive uses of water resources and management in Anambra State Nigeria. Natural and applied science journal 9(2). 2008 – 2014.
[5]. Ehirim, C. N. and Ebeniro, J. O. (2010). Evaluation of aquifer characteristics and groundwater potentials in Enugwu-Agidi, Awka, Nigeria Using vertical electrical sounding. Asian journal of earth Sciences 3(2) 73-81.